Airfiltech

LamiHosp Eco – laminar flow

Brands:
Availability: In Stock

Ceiling-mounted laminar flow filter housing for operating rooms, cost-optimized version, with the same airtightness standard as LamiHosp 2.

Category: Tag: SKU: LamiHosp-Eco-EN

Description

• Ceiling-mounted laminar flow filter housing designed specifically for hospital operating rooms.
• Supplies ultra-clean air directly to the surgical area, reducing the risk of airborne infection.
• Equipped with a pressure-drop test port and aerosol sampling port (test aerosol) accessible directly from inside the operating room.
• Filter replacement is performed from inside the room, with quick operation thanks to a locating-pin clamping device.
• Perforated mesh face panel/diffuser box ensures even air distribution and stable laminar flow.

Technical Specifications

  • Applications: Filter Housing mounted ceiling supply air series flow laminar (Laminar) for room operating.
  • Structure generate: Stainless steel SS304/SS430 or steel paint electrostatic (CSP).
  • Thickness: Housing: ~1,5mm, Side grille/Plate diffuser air: ~1,2mm.
  • Test port: 1 port connection test tra can contact access thereby side room operating to measure differential pressure and take sample air aerosol test tra (Test Aerosol).
  • Thay replacement filter: Thuc site thereby side during room, unit kep quick by the latch fixed position.
  • Degree tightness air of casing khung at 450Pa: Class B according to standard NF EN 1886:1998, Class L1 (M) according to standard PR EN 1886:2003, Class C according to standard PR EN 12237:2003.
  • Degree tightness air of gasket at 450Pa: Nho than 10-4 (0,01%) according to standard ISO EN 14644-3.
  • Options: The panel instruction instruction airflow fixed fixed.
  • Side grille/Housing diffusion diffusion: Type mesh perforated pore Ø8mm, area vent open 70% helps flow vent air easy easy.

Specification Table

Group Type Dimensions installation (mm) Area buildup ceiling/Area buildup area area filter (m2) Airflow 0.25 m/s (m3/h) Airflow 0.3 m/s (m3/h) Airflow 0.45 m/s (m3/h) Class air cleanroom class 40-45m2 Filter HEPA/ULPA 610x305x69 Filter HEPA/ULPA 610x610x69 Filter HEPA/ULPA 915x610x69 Filter HEPA/ULPA 1220x610x69
Lighting Series LH 1L 1965x1264x405 2.46/1.86 1,673 2,008 3,012 – 2     2
Lighting Series LH 1.5L 1970x1918x405 3.59/2.97 2,677 3,212 4,818 –   2 4  
Lighting Series LH 2L 2578x1965x405 5.07/4.09 3,680 4,416 6,624 ISO7   2 6  
Lighting Series LH 3L 2578x2620x455 6.75/5.58 5,017 6,020 9,030 ISO7     10  
Lighting Series LH 3.5L 3188x2620x455 8.30/7.06 6,359 7,631 11,446 ISO6-7     2 8
Lighting Series LH 4L 3231x3231x455 10.37/8.92 8,033 9,640 14,460 ISO6-7       12
Non – Lighting Series LH 1 1965x1264x405 2.46/2.23 2,008 2,410 3,615 –       3
Non – Lighting Series LH 1.5 1965x1920x405 3.77/3.35 3,010 3,612 5,418 –     6  
Non – Lighting Series LH 2 2620x1920x405 5.03/4.46 4,013 4,816 7,224 ISO7     8  
Non – Lighting Series LH 3 2620x2530x455 6.58/5.95 5,356 6,427 9,640 ISO7       8